Electrical Requirements for your Hot Tub
All Hot Tubs require a dedicated 240 volt, RCD protected electrical circuit that is permanently hard wired to the mains supply. (e.g. 32 amp, 45 amp supply).
Extension cords and plug-in type connectors must not be used. No other appliances or lights should be connected to this circuit
At the site where the Hot Tub is to be located, a local isolator must be placed 2 metres away from the Hot Tub. 5 metres of cable should then be left for the final connection of the Hot Tub.
All electrical wiring to a Hot Tub MUST be installed by a qualified, electrician.
Northern Hot Tubs can supply an electrician to install any electrical work required
Water should always drain away from the Hot Tub. DO NOT locate your Hot Tub in a low run-off area since rain or melting snow could flood the area and cause pump and equipment damage.
DO NOT locate your Hot Tub near or under overhead cables, and clear of all electrical appliances.